Technitium read down on one poll and up on the next, sixty seconds apart, and
the sev4 arrived after the service was already back.
mavpoll writes a service_down fact only when the state changes, so the fact's
timestamp IS the moment the monitor went down and its age is how long it has
stayed there. The debounce is that age against MinDownAge, 90s — one poll
interval plus jitter. No history to keep and no counter to persist.
It bounds the alarm and not the truth: DownServices still reports a monitor the
instant it goes down, because /dash showing a fresh outage is right even when
phoning him about it is not. Existing fixtures that seeded a one-minute-old
down fact now seed five, which is what they always meant.
It repeated every five minutes for over two hours. WasAcked was the only
stop condition and nothing reachable from telegram can mark a nudge acked
— the only ack is a voice 'готово' on a box that runs no voice loop.
Two endings now. The condition cleared, which the rule answers through the
new Rule.StillTrue — deliberately not Predicate, which is edge-triggered
and reads false one tick after the alarm is raised, so building the stop on
it would cancel every alarm immediately. Or the alarm got old, which is the
bound that needs no cooperation from the rule. A rule with no StillTrue is
never read as resolved and stops only on age.
Covered by tests including the flap case, since none of it can be
reproduced by hand without waiting hours.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
A rule over a key set that only exists at read time cannot declare its keys
at wiring time. Kuma has one monitor per service and the names live in the
gauge, so the rule declares a prefix and the gatherer resolves the family per
tick.
ServiceDownRule now fires on any monitor reading down, names it through
DownServices, and is edge-triggered: a service that stays down is one nudge,
not one per tick with cooldown as the only brake.
The kuma service_down nudge cannot name the service. mavpoll folds the whole
monitor_status gauge into one boolean fact keyed `service_down`, and the
phraser names a service only when the fact key is the service name, so the
message is always the generic "a service on homesrv is down". Every fifteen
minutes, with nothing to act on. A fact per monitor is the real fix and it is
filed as Vikunja #444; this is what to do until then.
`disabled_rules` in mavend.json subtracts from loop.DefaultRules by name.
Config only subtracts — rules stay code, the set stays canonical and ordered
as written. A disabled rule is not gathered for either, since the gatherer
derives its key set from the rules it was given. Unknown names are ignored so
deleting a rule cannot brick a config that still lists it, and the boot log
says what was dropped, because a rule that vanishes silently looks exactly
like a rule that is broken.
Deploy turns service_down off.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01TrVSBKe3RFDF4fGYKWYQnX
- Add CalendarEvents method to recordingAPI in auth_test.go
- Add CalendarEvents method to fakeCore in handlers_test.go
Co-Authored-By: opencode <opencode@anthropic.com>